Klik op het logo voor hulp op afstand
  
 
 
 
 
 
 
 




JoPPS INI parameters


 
SECTION
VALUE
DESCRIPTION
EXAMPLE

[Parameters]

%PROGRAM_ROOT%=
JoPPS program folder, equals the JoPPS startup folder if not specified.
C:\JoPPSWIN
Welcome=
Welcome Screen Once / Always or Never
0 / 1 or -1
ShowAllReports=
List all reports in combobox results
0 or 1
DisableScripts=
Disables ‘silent’ scripts (HTML)
0 or 1
Run0=
Runs specified script file before login. Can be used to automate user login. (eg. to disable the login prompt dialog)
 
Run=
Runs specified script file after login
 
FontSizes=
List of Font Sizes in pixels (1..7)
7,8,9,10,12,14,16
 
ThumbHints=
Controls wether hints is enabled in jopps thumbnails
0 or 1
ShowBanner=
Displays or hides the JoPPS wallpaper banner. (indicates the JoPPS version)
0=hide banner, 1=display banner
Logo=
Specifies the name of the logofile. The logofile can be a picture or an HTML document. Supported picture fileformats are BMP and JPG.
TECHWIN.BMP or
MYWALLPAPER.HTM
LogoAlign=
For picture logo's only. Determines the logo picture alignment.
0=no alignment, 1=align to top
2=align to bottom
3=align left
4=align right
LogoCenter=
For picture logo's only. Centers the logo picture. Only if LogoAlign=0
0=do not center, 1=center picture in middle of JoPPS background
LogoTransparent=
For picture logo's only. Determines transparancy for the logo picture.
0=draw picture normally
1=draw picture using transparency
LogoAutoSize=
For picture logo's only. Controls wether or not the picture should be sized to fit the JoPPS background.
0=draw picture at default size
1=draw picture as big as possible
LogoStretch=
For picture logo's only. Controls wether or not the picture should be stretched to fit the jopps background.
0=do not change picture proportions
1=alter proportions stretching the picture to fit the JoPPS background.

 

ExcelRangeValidation=

Check if range validation can be applied based on the language settings OFFICE and OS. 

 

0=never apply range validation
1= always apply range validation
2=check if range validation can be applied 

                                     
Filters=
After installing or upgrading JoPPS, a 'Welcome' screen appears at the first startup and is foreseen to activate the import filters of suppliers such as ANAF, SAINT-GOBAIN or WINKHAUS
0=do not permit import filters to be activated by default.
1=allow import filters to be activated by default.
  RowColor= Set the color of the row, to improve the contrast of the selected record in the table list view

clScrollBarclBackground, clActiveCaption, clInactiveCaption,
clMenu, clWindow, clWindowFrame, clMenuText, clWindowText,
clCaptionText, clActiveBorder, clInactiveBorder, clAppWorkSpace, 
clHighlight, clHighlightText, clBtnFace, clBtnShadow, clGrayText, 
clBtnText, clInactiveCaptionText, clBtnHighlight, cl3DDkShadow, 
cl3DLight, clInfoText, clInfoBk, clHotLight, clGradientActiveCaption,
clGradientInactiveCaption, clMenuHighlight, clMenuBar, clBlack,
clMaroon, clGreen, clOlive, clNavy, clPurple, clTeal, clGray, clSilver,
clRed, clime, clYellow, clBlue, clFuchsia, clAqua, clLtGray, clDkGray,
clWhite, clMoneyGreen, clSkyBlue, clCream, clMedGray,
clNone ,clDefault

  SelColor= Set the color of the selected row, to improve the contrast of the selected record in the table list view

clScrollBarclBackground, clActiveCaption, clInactiveCaption,
clMenu, clWindow, clWindowFrame, clMenuText, clWindowText, 
clCaptionText, clActiveBorder, clInactiveBorder, clAppWorkSpace,
clHighlight, clHighlightText, clBtnFace, clBtnShadow, clGrayText,
clBtnText, clInactiveCaptionText, clBtnHighlightcl3DDkShadow,
cl3DLight, clInfoText, clInfoBk, clHotLight, clGradientActiveCaption, 
clGradientInactiveCaption, clMenuHighlight, clMenuBar,clBlack,
clMaroon, clGreen, clOlive, clNavy, clPurple, clTeal, clGray, clSilver,
clRed, clime, clYellow, clBlue, clFuchsia, clAqua, clLtGray, clDkGray,
clWhite, clMoneyGreen, clSkyBlue, clCream, clMedGray, 
clNone ,clDefault

 
[Params]
User defined parameters, parameters can be used in user reports or scripts.
 
[MC]
where MC is the machinename
SBZ130, ELGO, Handtmann, Thorwesten
Common parameters per machine are :
MachineSetup=
Subfolder relative to the standard JoPPS DATA folder holding machine setup files. If not specified the MC driver will look for files in the DATA folder itself.
 
DumpTo=
Can be used to specify the name of optional temp. textfile holding the result of the internal MC query. For debug purposes only - if not specified (default) the file is not generated.
 
Corrections=
Controls the default behavior of the MC driver's "correct conflicting operations" setting.
This options is not supported by all MC drivers.
0=no corrections, 1=perform corrections
DGX=
Controls wether or not an optional DGX file is to be generated. This options is not supported by all MC drivers.
0=do not create DGX file
1=create DGX file
Note: Other MC driver specific settings are not discussed in this document.
 
[MCSetup]
Basedir=
Directory machine setup
C:\ JoPPSWIN\MSETUP
UseBatchCode=
Use batch code as default name for output file
0 or 1
 
[Paths]
JoppsSysDir=
Directory system tables
C:\JoPPSWIN\DBF
JoppsHlpDir=
Directory OnLine Help System
C:\JoPPSWIN\HLP
 
[BDE]
PdxNetDir=
Directory Paradox LockManager
C:\JoPPSWIN\DBF
PdxLangDriver=
Paradox Language Driver
ANSIINTL
 
[Language]
Language=
StartUp Language
0…4
LanDir=
Directory Language Tables
C:\JoPPSWIN\LAN
 
[Backup]
DaysBetweenBackups=
Number of days allowed between backups
5
 
[REPORT_xx]
 
xx=slotindex
38..42=user1..user5
50..53=user6..user9
54..56=user10..user12
Used=
Show report slot in results
0 or 1
Tag=
Caption of report slot in results
Record/Text
CanBatch=
Batch Mode Allowed
0 or 1
OutputType=
HTML/LABEL/TEXT/SCRIPT
0…3
RunScript=
Script Mode Allowed
0 or 1
Extension=
Alternative file extension
 
UseClientLanguage=
0=client language setting, 1=program language setting
0 or 1
ReportType=
xxx
where x = 0 or x = 1
Determines to which categories the report belongs :
100 means report belongs to "offer" reports, 010 means report belongs to "order" reports, "001" means report belongs to production.
 
[PriceTable]
Precision=
Decimal precision of prices
0
Filter=
PriceBlock for glazing, etc.
40,41,42
Detail=
Detail of prices
0..1
 
[Planning]
TableName=
Directory, name planning database
Planning.db
RequiredState=
Required state project for planning
0..6
PriceBlocks=
List of PriceBlocks
0,10,30,40,   ,90,91,92
 
[Keylock]
Port=
Scan specified port for MemoHASP
-2=NET scan
-1=USB scan
0..3=specifies LPT port
SrvName=
Use NetHASP License Manager with specified name
default ‘TechWIN’
CfgName=
Configuration file for NetHASP
 
TimeOut=
Specifies maximum idletime before license is freed for other user
TimeOut=60
(default 60 minutes)
Warning=
warn in days for timer license
number of days
Logging=
create a Hasp log file
1=create log file
 
[Optimization]
MultiCacheLeveln=
(n=1..4)
Internal meaning of the "Memory usage" Optimization parameter (values 1 thru 4 correspond with options 2 thru 5)
default 5, 8, 10 and 0
(allowed values are from 2 thru 10 and 0)
 
[SLE]
-9=LANDSCAPE A4
Default template for specific papertype (e.g. -9)
Negative values are landscape orientation
9=PORTRAIT A4
Default template for specific papertype (e.g. 9)
Positive values are portrait orientation
PaperType=9
Default papertype
 
 
[EOS]
Delay=
TimeOut=
UseTempEx=
Logging=
500 is Default
-1 = no time out
0 = no temporary file extension
0 = no logging
 
Delay=500
 
 

Section [Paths] allows a relative path specification (combined with startup directory), section [Language] needs a full path if specified


Instellingen JoPPS.INI  voor Machine sturing RA
  
De vaste parameters worden in Jopps.ini ingesteld, sectie: [NVDB_SETTINGS]. De variabele via het bestand Config.txt  
Deze configuratiebestanden kunnen makkelijk geopend worden via Werktuigen in Jopps (indien geïnstalleerd).  
  
JOPPS.INI  
  
MACHINE  Type machine (SBZ122 / SBZ130 / SBZ140)
  
CLIENT  Klantcode (toegewezen door RA)
  
SHOWTAG  Tonen van profielcodes (B1, B2, …) op etiketten en optimalisatie

 0: Niet tonen
 1: Wel tonen

COPY_CONFIG  Gebruik van CONFIG-parameters in Jopps

 0: Niet kopieren
 1: Kopieren op klantniveau (veld Opmerking)
 2: Kopieren op projectniveau (veld Opmerking)
 3: Kopieren op klant- en projectniveau (veld Opmerking)

LOGPROJECT  Loggen van projectinput

 0: Niet loggen
 1: Wel loggen

LOGDIR  Bestandspad van logbestanden (Standaard Config\Project)

VENT_CLAMP  Klemming vleugels 112 en 121 op machine

 0: Als deurprofiel
 1: Als raamprofiel     |     Geen deurbewerkingen toegelaten

CONFIG_DIR  Bestandspad van map CONFIG (Standaard Joppswin\Config)

DXF_DIR  Bestandspad van map DXF (standaard Joppswin\DXF)

 

Opmerking

Het jopps.ini bestand bevindt zich in de root map waarin JoPPS is geinstalleerd. 

 

 

 




 |  History  |
 
 

 
 
 
TECHWIN SOFTWARE
De Regenboog 11
B-2800 Mechelen
T +32(0)15 44 64 64
T +31(0)30 899 32 15 Nederland